FreeCooling
AirSite offers unique solutions for cooling of Telecom stations and other types of technology rooms without using conventional cooling machines. Save up to 90% of energy consumption with FreeCooling from AirSite.
Through the years, the product range has expanded, and today, we have a complete FreeCooling option for all types of technology rooms.
DeltaMaster is AirSite's best-seller, already in use at tens of thousands of telecommunications stations.
MicroMaster is a compact FreeCooling fan designed for smaller technology rooms where DeltaMaster 2 doesn't fit.
CarryMaster is AirSite's portable emergency fan.
CityMaster is the perfect FreeCooling solution for central technology rooms where low noise is a top priority.
ODU is AirSite's outdoor FreeCooling unit.
Calculate and dimension your FreeCooling system with the help of DeltaMaster Calculation.
DeltaMaster - For Telecom stations and technical rooms
DeltaMaster is a unique market solution for telecom stations. The function involves a fresh air unit pushing clean air into the room without mixing it. Stratifying the air causes the warm air to rise to the ceiling and then exit through an exhaust grille.
DeltaMaster has a built-in temperature sensor and automatically adjusts fan speed as needed, according to the setpoint values in the included control unit.
AirSite's popular control unit, DeltaManager, is packed with features! In addition to the ability to set values for adjustment and reading, DeltaManager also offers a range of other functions. This includes standard damper control, a log of the latest alarms, a start signal for the cooling machine, more connection options via analog and digital inputs, advanced network functions via Modbus TCP for remote control and monitoring.
Today, we offer DeltaMaster in 48V and 230V versions with cooling capacities* ranging from 2kW to 12kW, with as low a ∆T as 2°C.
DeltaMaster 48EC units are designed for telecom applications with 48V power supply. Our advanced control units regulate the fan continuously and have special modes for fire or power outage. It is also very easy to reprogram the control unit if additional special functions are desired.
DeltaMaster 230EC units are designed for technical rooms with 230V power supply.
We have a comprehensive list of accessories including air heaters, intake hoods, exhaust hoods, damper systems, roof hoods, grilles, communication products for monitoring, and more.
*By cooling capacity, we mean the heat load that the free cooling can ventilate away.
MicroMaster - For smaller technical rooms
MicroMaster is a small FreeCooling unit designed for smaller technical rooms where a DeltaMaster would be oversized or in situations where larger units can not fit. Today, we offer MicroMaster in 48V and 230V versions.
MicroMaster 48EC units are designed for telecom applications with a 48V power supply. Our advanced control units regulate the fan continuously and have special modes for fire or power outage. It is also very easy to reprogram the control unit if additional special functions are desired.
MicroMaster 230EC units are designed for technical rooms with a 230V power supply.
CityMaster - For minimal noise
FreeCooling unit with additional sound reduction thanks to sound-absorbing mineral wool inside the unit. Suitable for densely populated areas and where there are requirements for low noise levels. Available in both upward and rear connections.
Our popular control unit, DeltaManager, works equally well with CityMaster and is packed with features! In addition to the ability to set values for adjustment and reading, DeltaManager also offers a range of other functions. This includes standard damper control, a log for the 10 most recent alarms, a start signal for the cooling machine, more connection options via analog and digital inputs, advanced network functions via Modbus TCP for remote control and monitoring. DeltaManager uses cable penetrations that meet IP54 standards."
ODU (Outdoor Unit) - When there is limited indoor space
ODU is specially designed for telecom sites where a DeltaMaster unit cannot fit indoors. The entire unit is mounted on the outside of the equipment room.
Just like DeltaMaster, ODU includes a temperature sensor and automatically adjusts fan speed as needed, according to the setpoint values in the control unit.
Our popular control unit, DeltaManager, works equally well with ODU and is packed with features! In addition to the ability to set values for adjustment and reading, DeltaManager also offers a range of other functions. This includes standard damper control, a log for the 10 most recent alarms, a start signal for the cooling machine, more connection options via analog and digital inputs, advanced network functions via Modbus TCP for remote control and monitoring. DeltaManager is rated to IP54 standards for tightness.
ODU 48EC units are designed for telecom applications with a 48V power supply. Our advanced control units regulate the fan continuously and have special modes for fire or power outage. It is also very easy to reprogram the control unit if additional special functions are desired.
ODU 230EC units are designed for technical rooms with a 230V power supply.
CarryMaster - Portable emergency fan
Portable FreeCooling fan suitable for temporary cooling requirements with a 230V EC fan.
The fan is controlled by a temperature regulator that adjusts the fan speed from 10°C = 10% to 45°C = 100%